Cleanroom classification is a particle concentration, not a cleaning standard. A room can be ISO Class 5 at rest and fail in operation; a wiper can be low-particle on the data sheet and still shed at the edge. The specification has to connect the room class, the operating state and the way the cloth is handled.
For wipers, the practical question is simpler: what can the cloth leave behind on this surface, and what does the audit expect you to prove? That is where material, edge and lot data come in.
What ISO 14644-1 actually controls
ISO 14644-1 classifies a cleanroom by the maximum permitted concentration of airborne particles at a specified size. The class number is logarithmic: each step changes the allowed concentration by roughly a factor of ten. The classification can be stated “at rest” or “in operation”, and the two are not interchangeable.
A wiper specification is not a room classification. It is a contamination-control decision: the cloth must not add particles, fibers or extractables to the surface while it removes the soil. That is why two wipers in the same ISO class can have very different prices and very different audit value.
ISO 3–8 at a glance
| ISO class | Fed Std 209E | Typical GMP zone | ≥0.5 µm / m³ | Wiper specification |
|---|---|---|---|---|
| ISO 3 | Class 1 | Advanced semiconductor / R&D | 35 | Sealed polyester or microfiber; sterile where required; lot LPC/NVR |
| ISO 4 | Class 10 | Grade A/B (at rest) | 352 | Laser-sealed polyester; low NVR and ions; double-bagged |
| ISO 5 | Class 100 | Grade A/B | 3,520 | Laser or ultrasonic sealed polyester/microfiber |
| ISO 6 | Class 1,000 | Grade B/C | 35,200 | Sealed polyester or cellulose/polyester blend |
| ISO 7 | Class 10,000 | Grade C/D | 352,000 | Cellulose/polyester or sealed microfiber |
| ISO 8 | Class 100,000 | Grade D | 3,520,000 | Cut-edge cellulose/polyester or general cleanroom wipe |
Read the table as a starting point, not a legal equivalence. EU GMP grades and ISO classes are related but not identical; the operating state and the validation plan decide the final specification. Particle counts are the ISO 14644-1:2015 limits for ≥0.5 µm.
The three tests behind a wiper claim
Particle release (LPC)
Liquid particle count measures the particles a wiper releases when it is rinsed or wrung in filtered water. It is the first number to ask for on a cleanroom wiper, and it should be reported per lot — not as a single marketing figure.
Non-volatile residue (NVR)
NVR measures what remains after a solvent extract evaporates. It matters most after IPA, acetone or MEK, when a film can interfere with a coating, a bond or an analytical result. The test method and the limit matter as much as the number.
Ionic extractables
Ionic contamination is measured by ion chromatography. Chloride, sulfate, sodium and other ions can corrode a tool or interfere with a process. A low-particle wiper can still have high ionic extractables if the fiber or the finishing is wrong.
For sterile wipers, add sterility assurance and, where relevant, endotoxin testing. Sterility is a separate attribute from particle class; a sterile wipe is not automatically low-NVR, and a low-NVR wipe is not automatically sterile.
Edge, material and class
The edge is the first thing to fail in a high-class room. A cut edge releases fibers from the cut line; a laser or ultrasonic sealed edge locks them in. For ISO 3–6, specify a sealed edge. For ISO 7–8, a cut edge can be acceptable where the soil load is the main problem and the room is not critical.
The material follows the soil. Polyester and microfiber for solvent and low-particle work; cellulose/polyester for faster degreasing; mesh rayon for dust; meltblown PP for oil, not for a critical surface. The room class sets the edge and the documentation; the soil sets the fiber.
What to ask for in a lot file
- COA with LPC, NVR and ionic results for the lot, not a generic brochure.
- Test method — IEST-RP-CC004, SEMI or the internal method, stated clearly.
- Traceability — fiber lot, converting line, packing date and carton code.
- Sterility — gamma dose and sterility assurance letter where the zone requires it.
Frequently asked questions
What ISO class wiper do I need for ISO Class 5?
A sealed-edge polyester or microfiber wiper with lot particle, NVR and ionic data. A cut-edge cellulose blend is not the right specification for an ISO Class 5 critical surface, even if the room is only Class 5 at rest.
Is ISO 7 the same as Class 10,000?
It is the usual equivalence for the older US Federal Standard 209E. ISO 7 allows 352,000 particles ≥0.5 µm per cubic metre; Class 10,000 allowed 10,000 particles per cubic foot, which is approximately the same concentration.
Do I need sterile wipes in ISO Class 7?
Not automatically. Sterility is a separate requirement from particle class. A Grade C zone may need low-bioburden rather than sterile wipes; a Grade A/B zone usually needs sterile, gamma-irradiated wipers. Confirm with your validation plan.
What is NVR and why does it matter?
Non-volatile residue is what remains after a solvent evaporates. A wiper with high NVR leaves a film on the surface, which can interfere with coatings, bonding or analytical results. Ask for the test method and the limit, not just a “low NVR” claim.
Next step
Match the wiper to the room, not the catalogue.
Send the ISO class, the operating state and the surface. We will confirm the edge, the material and the lot data you need.
Ask a specification engineer